We Power Your Technology!

ER34615 Cylindrical Lithium Battery

Overview
HCB offers high quality ER34615 Li-SOCl2 Lithium Thionyl Chloride 3.6v D primary battery to clients all over the world.
It can be used for water meter, electricity meter, gas meter, heat meter, automatic meter reading system. Get Our Catalog Now!
Description Specification Drawing
Description
Product Details of ER34615 Li-SOCl2 Cylindrical Battery
Bobbin Type 19000mAh 3.6V Lithium-thionyl chloride [Li-SOCl2] D-size ER34615 Lithium Battery for water meter, electricity meter, gas meter, heat meter, Automatic Meter Reading system.
Advantage of ER34615 Li-SOCl2 Cylindrical Battery
  • High and Stable Voltage
  • Energy Density up to 590Wh/kg
  • Long Shelf Life (less than 1% per year after 1 year of storage at +25℃)
  • Wide Operating Temperature (-55℃~+85℃)
Primary Lithium Battery ER34615 3.6V Lithium-thionyl chloride [Li-SOCl2] D size bobbin type ER34615
Place of Origin PRC
Brand Name HCB PRIMARY LITHIUM BATTERY
Certification UN/CE/UL
Model Number ER34615
Specification
Specification of ER34615 Li-SOCl2 Cylindrical Battery
Characteristics Open circuit voltage (at 25°C) ≥3.65V
Electrical characteristics Nominal capacity 19000mAh
(At +25°C, battery discharged at continuous current 0.65mA until voltage reaches cut-off voltage 2.0V. The capacity can vary at different temperature, discharge current or cut-off voltage. ) (At +25°C, battery discharged at continuous current 0.65mA until voltage reaches cut-off voltage 2.0V. The capacity can vary at different temperature, discharge current or cut-off voltage. )
Maximum continuous current 250mA
(At +25°C, 2.0V cut-off, battery discharged for minimum 50% of nominal capacity. ) (At +25°C, 2.0V cut-off, battery discharged for minimum 50% of nominal capacity. )
Maximum pulse discharge current 400mA
(At +25°C, 2.0V cut-off, battery discharged for minimum 50% of nominal capacity with max pulse for 3 seconds after 27 seconds break. The discharged capacity may vary according to the pulse characteristics, the temperature, and the cell’s previous history. Fitting the cell with a capacitor may be recommended in severe conditions, consult HCB.) (At +25°C, 2.0V cut-off, battery discharged for minimum 50% of nominal capacity with max pulse for 3 seconds after 27 seconds break. The discharged capacity may vary according to the pulse characteristics, the temperature, and the cell’s previous history. Fitting the cell with a capacitor may be recommended in severe conditions, consult HCB.)
Storage (recommended) ≤+30°C
(For more severe conditions, consult HCB) ≤75%RH
Operating temperature range -55°C~+85°C
(Operation above ambient temperature may lead to reduced capacity and lower voltage readings at the beginning of pulses, consult HCB.) (Operation above ambient temperature may lead to reduced capacity and lower voltage readings at the beginning of pulses, consult HCB.)
Physical characteristics Diameter 32.9±0.3mm
Height 60.4±0.8mm
Typical weight 105.0g
Li metal content 5.3g
Drawing
Drawing of ER34615 Li-SOCl2 Cylindrical Battery